Draft Parameters for SiC/SiC Blanket with LiPb as Coolant for FW and Blanket and a Replaceable FW/Blanket Region |
|
|
Radial Thicknesses (m) |
|
|
Replaceable FW/Blanket Region |
2.50E-01 |
|
Permanent FW/Blanket Region |
4.50E-01 |
|
FW + Blanket Coolant |
LiPb |
|
Mass Flow Rate (kg/s) |
2.82E+04 |
|
Inlet Temperature (°C) |
7.18E+02 |
|
Outlet Temperature (°C) |
1.15E+03 |
|
Pressure Drop (Mpa) |
2.60E-01 |
|
Pumping Power (MW) |
9.38E-01 |
|
First Wall Assuming Tapering Channels |
|
|
Outboard Midplane Channel Diameter (m) |
3.00E-02 |
|
Outboard Midplane Channel Pitch (m) |
3.80E-02 |
|
FW Region Radial Thickness (m) |
3.60E-02 |
|
LiPb Velocity (m/s) |
2.68E+00 |
|
Heat Transfer Coefficient (W/m2-K) |
1.49E+04 |
|
Pressure Drop (MPa) |
2.57E-01 |
|
Maximum SiC Temperature (°C) |
1.00E+03 |
|
SiC/SiC Ribs + Walls (Except FW) |
|
|
Thickness (m) |
3.40E-02 |
|
Channel Diameter (m) |
3.00E-02 |
|
Channel Pitch (m) |
3.30E-02 |
|
LiPb Velocity (m/s) |
3.56E-01 |
|
Heat Transfer Coefficient (W/m2-K) |
6.94E+03 |
|
Pressure Drop (MPa) |
3.20E-03 |
|
Maximum SiC/LiPb Temperature (°C) |
9.11E+02 |
|
Main LiPB Channels (In Replaceable Section as Example) |
|
|
Toroidal Dimension (m) |
2.57E-01 |
|
Hydraulic Diameter (m) |
2.10E-01 |
|
LiPb Velocity (m/s) |
1.47E-01 |
|
Heat Transfer Coefficient (W/m2-K) |
1.61E+03 |
|
Pressure Drop (MPa) |
2.06E-04 |