Safety and Environmental Guidance for Fusion Conceptual Design Studies

ARIES Electronic Project Meeting
December 4, 1998


Worker Dose Limits and Administrative Guidelines


Previous Slide
Accident Considerations
Next Slide
Minimizing Waste

 

Worker Dose Limits

Proposal

Value

Comment

Limit for annual individual worker doses

50 mSv and 20 mSv averaged over 5 yrs

IAEA proposal. (Also consistent with EUR: European Utility Requirements for future fission plants. Similar to US DOE rqmts)

Administrative Guidelines

Proposal

Value

Comment

Administrative guideline for annual individual worker doses

5 mSv

Consistent with EUR. Typically Facility Limits are 10 times smaller compared to limits. (factor 4 smaller than ITER FDR)

ALARA threshold for activities with doses larger than

0.5 mSv/shift

Dose guideline for single shift should be 10 times smaller compared to annual dose guideline (factor 4 smaller than ITER FDR)

ALARA threshold for dose rates

100 micro-Sv/h

 

Collective annual worker dose target averaged over life time of plant

0.5 man-Sv

EUR target: 0.7 man-Sv/GWe

ALARA review of all activities exceeding collective worker dose

30 person mSv/yr

Collective dose target for each activity

10 mSv = 1 Rem; 100 micro-Sv/hr = 10 mrem/hr