Divertor System Final Design and Key Issues

ARIES Electronic Project Meeting
December 4, 1998


Design Summary


Previous Slide
Material Issues
Next Slide
Summary and Key Issues

Geometry

Cross section of lower divertor

Tube shape

Tube internals

Manifold connection

Materials:

Plasma-facing materialpure W
Structurepure W
Heat sinkporous W
ManifoldingFerritic steel
CoolantHe at 12 MPa
Main parameters:

Total divertor area113 m2
Transport power451 MW (up from 345 MW in J-strawman)
Inboard/outboard power split10/90%
Average outboard divertor heat flux3.6 MW/m2
Peak divertor heat flux (assumed)5 MW/m2
.
Length of divertor plates1.5 m
PMHX pipe ID/OD2.4/2.8 cm

Performance Metrics

Inlet/outlet temperature350/550 °C
Peak surface temperature816 °C
Peak stress393 MPa